- Scope and content:
-
A collection of documents pertaining to Dr. Oscar Wyss's modification of an oxygen generator manufactured by Mine Safety Appliances in Pittsburgh, Penn. for use by climbers during the 1951 Swiss Everest Expedition. The collection includes correspondence among Dr. Wyss and members of the 1951 Swiss Everest Team, background literature about oxygen generators, a brief report of the 1951 Swiss expedition, newsclippings about the 1951 Swiss expedition and the 1953 British expedition to Everest, and photographs of the device.
- Biographical / historical:
-
Dr. Oscar Wyss was a Swiss physiologist associated with the Physiologisches Institut der Universitat Zurich.
In 1950, Dr. Wyss modified an oxygen generator for use by the Swiss climbing team during its 1951 Everest Expedition. Dr. Wyss's model was the oxygen generator manufactured by Mine Safety Appliances of Pittsburgh, Penn., for use in coal mining.
A closed circuit system, the generator weighed less than five pounds and could be easily carried on the abdomen of a climber. It used potassium dioxide to break down the water in respiration into potassium hydroxide and oxygen, the latter to be inhaled by a climber wearing the device. A climber could use the device to support breathing for up to forty-five minutes independent of the air supply present in the environment. Opening the circuit to include the local atmosphere could extend the life of the device even longer.
Wyss's modification was unsuccessful. The volume of moisture contained in exhaled air at high altitude is considerably less than at sea level. Thus, the device's ability to produce oxygen at high altitude was greatly diminished. Also, Wyss had designed the device with a stiff, inflexible breathing tube, making it impossible to use the device while actually climbing.
The failure of the device contributed significantly to the failure of the Swiss team to reach the summit of Mt. Everest.
The collection was given to John B. West in 1998 by Dr. E. A. Koller of the Physiologisches Institut der Universitat Zurich.
- Physical location:
- For current information on the location of these materials, please consult the Library's online catalog.
- Physical description:
- 0.40 linear feet (1 archives box and 1 shoe box)
About this collection guide
- Date Prepared:
- © 1997
- Date Encoded:
- Machine-readable finding aid derived from database output.
Access and use
- Preferred citation:
-
Oscar Wyss Oxygen Generator Files., MSS 0466. Mandeville Special Collections Library, UCSD.
- Location of this collection:
-
9500 Gilman Drive, Dept. 0175La Jolla, CA 92093-0175, US
- Contact:
- (858) 534-2533